3.10 : Hotels/Motels
| 3.10.7 |
Energy
Benchmarks for Existing Small Hotels, by Selected City and End-Use |
|
|
|
|
|
|
(thousand Btu per square foot) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IECC |
|
|
Heating |
|
Cooling |
|
Water Heating |
|
Ventilation |
|
|
|
Climate Zone |
|
Post |
Pre |
|
Post |
Pre |
|
Post |
Pre |
|
Post |
Pre |
|
| Miami |
|
|
1A |
|
|
0.2 |
0.0 |
|
25.7 |
21.2 |
|
5.6 |
5.4 |
|
6.7 |
2.6 |
|
| Houston |
|
|
2A |
|
|
2.8 |
0.7 |
|
17.7 |
16.1 |
|
6.7 |
6.5 |
|
5.6 |
2.0 |
|
| Phoenix |
|
|
2B |
|
|
2.0 |
0.2 |
|
18.7 |
17.0 |
|
6.0 |
5.9 |
|
6.2 |
2.3 |
|
| Atlanta |
|
|
3A |
|
|
5.4 |
1.9 |
|
12.0 |
11.1 |
|
7.8 |
7.6 |
|
5.4 |
1.6 |
|
| Los Angeles |
|
3B |
|
|
1.7 |
0.0 |
|
9.5 |
9.7 |
|
7.6 |
7.4 |
|
5.2 |
1.4 |
|
| Las Vegas |
|
3B |
|
|
3.4 |
0.6 |
|
13.6 |
13.5 |
|
6.8 |
6.6 |
|
5.7 |
1.9 |
|
| San Francisco |
|
3C |
|
|
4.4 |
0.3 |
|
5.8 |
6.1 |
|
8.5 |
8.3 |
|
4.5 |
0.9 |
|
| Baltimore |
|
4A |
|
|
9.2 |
3.7 |
|
9.6 |
8.8 |
|
8.6 |
8.4 |
|
4.9 |
1.3 |
|
| Albuquerque |
|
4B |
|
|
5.9 |
1.8 |
|
8.8 |
8.8 |
|
8.4 |
8.2 |
|
5.5 |
1.4 |
|
| Seattle |
|
|
4C |
|
|
7.6 |
2.0 |
|
4.9 |
5.0 |
|
9.1 |
8.8 |
|
4.6 |
0.8 |
|
| Chicago |
|
|
5A |
|
|
13.5 |
5.2 |
|
7.8 |
6.9 |
|
9.4 |
9.1 |
|
4.9 |
1.1 |
|
| Boulder |
|
|
5B |
|
|
9.1 |
3.2 |
|
6.8 |
6.4 |
|
9.3 |
9.1 |
|
5.3 |
1.1 |
|
| Minneapolis |
|
6A |
|
|
18.3 |
8.8 |
|
7.4 |
6.5 |
|
10.0 |
9.7 |
|
4.8 |
1.1 |
|
| Helena |
|
|
6B |
|
|
14.2 |
5.8 |
|
5.1 |
5.0 |
|
10.1 |
9.9 |
|
5.0 |
1.0 |
|
| Duluth |
|
|
7 |
|
|
22.8 |
11.6 |
|
4.9 |
4.2 |
|
11.1 |
10.8 |
|
4.6 |
0.9 |
|
| Fairbanks |
|
8 |
|
|
41.6 |
26.7 |
|
3.9 |
3.1 |
|
12.3 |
12.0 |
|
4.6 |
1.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Note(s): |
Commercial
building energy benchmarks are based off of the current stock of commercial
buildings and reflect 2004 ASHRAE 90.1 Climate Zones. They are designed to
provide a consistent baseline to compare building performance in energy-use
simulations. 'Post' refers to buildings construction in or after 1980. 'Pre'
refers to buildings construction before 1980. The benchmark building had
43,186 square feet and 4 floors. Benchmark interior lighting energy = 21.51
thousand Btu/SF. Interior equipment energy consumption = 21.98 thousand
Btu/SF. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|