3.1 : Commercial Sector Energy Consumption
| 3.1.5 |
2015 Commercial
Energy End-Use Splits, by Fuel Type (Quadrillion Btu) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Natural |
Fuel |
|
Other |
Renw. |
Site |
|
Site |
|
Primary |
Primary |
|
|
|
|
Gas |
Oil (1) |
LPG |
Fuel(2) |
En.(3) |
Electric |
|
Total |
Percent |
Electric (4) |
|
Total |
Percent |
| Lighting |
|
|
|
|
|
|
|
1.01 |
|
1.01 |
11.4% |
| |
3.05 |
|
3.05 |
16.7% |
|
| Space Heating |
|
1.69 |
0.20 |
|
0.06 |
0.11 |
0.17 |
|
2.23 |
25.2% |
| |
0.50 |
|
2.57 |
14.1% |
|
| Space Cooling |
|
0.04 |
|
|
|
|
0.51 |
|
0.54 |
6.1% |
| |
1.52 |
|
1.56 |
8.6% |
|
| Ventilation |
|
|
|
|
|
|
0.54 |
|
0.54 |
6.1% |
| |
1.62 |
|
1.62 |
8.9% |
|
| Refrigeration |
|
|
|
|
|
|
0.35 |
|
0.35 |
4.0% |
| |
1.06 |
|
1.06 |
5.8% |
|
| Electronics |
|
|
|
|
|
|
0.32 |
|
0.32 |
3.6% |
| |
0.95 |
|
0.95 |
5.2% |
|
| Water Heating |
|
0.48 |
0.03 |
|
|
0.03 |
0.09 |
|
0.63 |
7.1% |
| |
0.27 |
|
0.81 |
4.5% |
|
| Computers |
|
|
|
|
|
|
0.19 |
|
0.19 |
2.1% |
| |
0.57 |
|
0.57 |
3.1% |
|
| Cooking |
|
|
0.19 |
|
|
|
|
0.02 |
|
0.21 |
2.4% |
| |
0.07 |
|
0.26 |
1.4% |
|
| Other (5) |
|
|
0.33 |
0.01 |
0.14 |
0.05 |
0.01 |
0.81 |
|
1.35 |
15.2% |
| |
2.45 |
|
2.99 |
16.4% |
|
| Adjust to SEDS
(6) |
0.68 |
0.19 |
|
|
|
0.63 |
|
1.50 |
16.9% |
| |
1.90 |
|
2.77 |
15.2% |
|
| Total |
|
|
3.33 |
0.43 |
0.14 |
0.11 |
0.15 |
4.63 |
|
8.88 |
100% |
| |
13.99 |
|
18.23 |
100% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Note(s): |
1)
Includes (0.35 quad) distillate fuel oil and (0.08 quad) residual fuel oil.
2) Kerosene (less than 0.01 quad) and coal (0.06 quad) are assumed
attributable to space heating. Motor gasoline (0.05 quad) assumed
attributable to other end-uses. 3) Comprised of (0.11 quad) biomass, (0.03
quad) solar water heating, (less than 0.01 quad) solar PV, and (less than
0.01 quad) wind. 4) Site-to-source electricity conversion (due to generation
and transmission losses) = 3.02. 5) Includes service station equipment, ATMs,
telecommunications equipment, medical equipment, pumps, emergency electric
generators, combined heat and power in commercial buildings, and
manufacturing performed in commercial buildings. 6) Energy adjustment EIA
uses to relieve discrepancies between data sources. Energy attributable to
the commercial buildings sector, but not directly to specific end-uses. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DOWNLOAD TABLE AS PDF XLS
Related Tables:
Sources:
| EIA, National Energy Modeling System (NEMS) for AEO 2012 Early Release, Jan. 2012
|
|
|