2.1 : Residential Sector Energy Consumption
| 2.1.15 |
Aggregate
Residential Building Component Loads as of 1998 (1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Load (quads) and Percent of Total
Load |
|
|
|
|
|
|
|
|
| Component |
|
|
|
Heating |
|
Cooling |
|
|
|
|
|
|
|
|
| Roof |
|
|
|
|
-0.65 |
12% |
|
0.16 |
14% |
|
|
|
|
|
|
|
|
| Walls |
|
|
|
|
-1.00 |
19% |
|
0.11 |
10% |
|
|
|
|
|
|
|
|
| Foundation |
|
|
|
-0.76 |
15% |
|
-0.07 |
- |
|
|
|
|
|
|
|
|
| Infiltration |
|
|
|
-1.47 |
28% |
|
0.19 |
16% |
|
|
|
|
|
|
|
|
| Windows
(conduction) |
|
|
-1.34 |
26% |
|
0.01 |
1% |
|
|
|
|
|
|
|
|
| Windows (solar
gain) |
|
|
0.43 |
- |
|
0.37 |
32% |
|
|
|
|
|
|
|
|
| Internal Gains |
|
|
|
0.79 |
- |
|
0.31 |
27% |
|
|
|
|
|
|
|
|
| Net Load |
|
|
|
-3.99 |
100% |
|
1.08 |
100% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Note(s): |
1)
"Load" represents the thermal energy losses/gains that when
combined will be offset by a building's heating/cooling system to maintain a
set interior temperature (which equals site energy). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|